Husky 1050 Air-Operated Double Diaphragm Pumps 1″

$1,595.00 inc. GST

Husky 1050 Air-Operated Double Diaphragm Pumps 1 inch Positive Displacement Double Diaphragm Pump

AODD pumps with 1 inch (25.4 mm) connection available in aluminum, polypropylene, conductive polypropylene, PVDF, stainless steel and hastelloy

Our 1 inch (25.4 mm) Husky 1050 pneumatic double diaphragm pumps feature a stall-free, low pulsation air valve which provides a smooth and rapid changeover. Available in aluminum, polypropylene, conductive polypropylene, PVDF, stainless steel and hastelloy fluid sections.

Husky 1050 Air-Operated Diaphragm Pump
Maximum fluid working pressure125 psi
Air pressure operating range20-125 psi
Fluid displacement per cycle0.17 gal
Air consumption25 scfm at 70 psi, 20 gpm
Maximum values with water as media under submerged inlet conditions at ambient temperature:
Maximum air consumption67 scfm
Maximum free-flow delivery50 gpm
Maximum pump speed280 cpm
Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables)16 ft dry, 29 ft wet
Maximum size pumpable solids1/8 in
Recommended cycle rate for continuous use93 – 140 cpm
Recommended cycle rate for circulation systems20 cpm
Sound Power*
at 70 psi (4.8 bar, 0.48 MPa) and 50 cpm78 dBa
at 100 psi (7.0 bar, 0.7 MPa) and full flow90 dBa
Sound Pressure**
at 70 psi (4.8 bar, 0.48 MPa) and 50 cpm84 dBa
at 100 psi (7.0 bar, 0.7 MPa) and full flow96 dBa
Fluid temperature rangeSee Manual
Air inlet size1/2 npt(f)
Fluid inlet size
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S)1 in npt(f) or 1 in bspt
Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F)1 in raised face ANSI/DIN flange
Fluid outlet size
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S)1 in npt(f) or 1 in bspt
Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F)1 in raised face ANSI/DIN flange
Weight
Aluminum (1050A)23 lb
Conductive Polypropylene (1050C) and Polypropylene (1050P)18 lb
Hastelloy (1050H)41 lb
PVDF (1050F)26 lb
Stainless Steel (1050S) with conductive polypropylene center36.3 lb
Stainless Steel (1050S) with polypropylene center37.3 lb
Stainless Steel (1050S) with aluminum center41.4 lb
Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus the pump’s material of construction
1050AAluminum
1050HHastelloy
1050C and 1050PPolypropylene
1050FPVDF
1050SStainless Steel
Non-wetted external parts
Aluminum (1050A)aluminum, coated carbon steel
Hastelloy (1050H)hastelloy, stainless steel, polypropylene or aluminum (if used in center section)
Plastic (1050P, 1050C, and 1050F)stainless steel, polypropylene
Stainless Steel (1050S)stainless steel, polypropylene or aluminum (if used in center section)
Reference Information
Maximum Storage Time (varies with conditions)2 years
Maximum Lifetime (varies with operating conditions and maintenance)10 years
Power Efficiency Factor (varies based on pump configuration, operating parameters, and material)1.61 gal air consumed/1 gal fluid pumped at 70 psi
* Sound power measured per ISO-9614–2. ** Sound pressure was tested 3.28 ft (1 m) from equipment. All trademarks mentioned in this manual are the property of their respective owners.
SKU: 647040 Categories: ,
Brand:Graco
Description

Description

Husky 1050 Air-Operated Double Diaphragm Pumps 1 inch Positive Displacement Double Diaphragm Pump

AODD pumps with 1 inch (25.4 mm) connection available in aluminum, polypropylene, conductive polypropylene, PVDF, stainless steel and hastelloy

Our 1 inch (25.4 mm) Husky 1050 pneumatic double diaphragm pumps feature a stall-free, low pulsation air valve which provides a smooth and rapid changeover. Available in aluminum, polypropylene, conductive polypropylene, PVDF, stainless steel and hastelloy fluid sections.

Husky 1050 Air-Operated Diaphragm Pump
Maximum fluid working pressure125 psi
Air pressure operating range20-125 psi
Fluid displacement per cycle0.17 gal
Air consumption25 scfm at 70 psi, 20 gpm
Maximum values with water as media under submerged inlet conditions at ambient temperature:
Maximum air consumption67 scfm
Maximum free-flow delivery50 gpm
Maximum pump speed280 cpm
Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables)16 ft dry, 29 ft wet
Maximum size pumpable solids1/8 in
Recommended cycle rate for continuous use93 – 140 cpm
Recommended cycle rate for circulation systems20 cpm
Sound Power*
at 70 psi (4.8 bar, 0.48 MPa) and 50 cpm78 dBa
at 100 psi (7.0 bar, 0.7 MPa) and full flow90 dBa
Sound Pressure**
at 70 psi (4.8 bar, 0.48 MPa) and 50 cpm84 dBa
at 100 psi (7.0 bar, 0.7 MPa) and full flow96 dBa
Fluid temperature rangeSee Manual
Air inlet size1/2 npt(f)
Fluid inlet size
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S)1 in npt(f) or 1 in bspt
Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F)1 in raised face ANSI/DIN flange
Fluid outlet size
Aluminum (1050A), Hastelloy (1050H) or Stainless Steel (1050S)1 in npt(f) or 1 in bspt
Conductive Poly (1050C), Polypropylene (1050P), or PVDF (1050F)1 in raised face ANSI/DIN flange
Weight
Aluminum (1050A)23 lb
Conductive Polypropylene (1050C) and Polypropylene (1050P)18 lb
Hastelloy (1050H)41 lb
PVDF (1050F)26 lb
Stainless Steel (1050S) with conductive polypropylene center36.3 lb
Stainless Steel (1050S) with polypropylene center37.3 lb
Stainless Steel (1050S) with aluminum center41.4 lb
Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus the pump’s material of construction
1050AAluminum
1050HHastelloy
1050C and 1050PPolypropylene
1050FPVDF
1050SStainless Steel
Non-wetted external parts
Aluminum (1050A)aluminum, coated carbon steel
Hastelloy (1050H)hastelloy, stainless steel, polypropylene or aluminum (if used in center section)
Plastic (1050P, 1050C, and 1050F)stainless steel, polypropylene
Stainless Steel (1050S)stainless steel, polypropylene or aluminum (if used in center section)
Reference Information
Maximum Storage Time (varies with conditions)2 years
Maximum Lifetime (varies with operating conditions and maintenance)10 years
Power Efficiency Factor (varies based on pump configuration, operating parameters, and material)1.61 gal air consumed/1 gal fluid pumped at 70 psi
* Sound power measured per ISO-9614–2. ** Sound pressure was tested 3.28 ft (1 m) from equipment. All trademarks mentioned in this manual are the property of their respective owners.